Running a portable gasoline generator costs about $0.45 to $3.03 an hour in fuel, and a 10 to 26 kW home standby generator about $1.51 to $10.49 an hour, depending on size, load and fuel. We worked these figures out from the tank sizes, run times and fuel-use tables that Honda, Westinghouse, Champion and Generac publish, priced at US average fuel prices from the Energy Information Administration (EIA), including gasoline at $3.805 a gallon on 16 November 2026. Per kilowatt-hour, generator power costs roughly three to five times as much as grid electricity. Checked 22 November 2026.
| Grade / Item | Low | High | Unit |
|---|---|---|---|
| Honda EU2200i, gasoline (1/4 load to rated) | $0.45 | $1.13 | USD/hour |
| Honda EU3200i, gasoline (1/4 load to rated) | $0.53 | $1.38 | USD/hour |
| Honda EU7000iS, gasoline (1/4 load to rated) | $1.21 | $3.03 | USD/hour |
| Westinghouse WGen7500, gasoline (25% load) | $2.28 | $2.28 | USD/hour |
| Champion 201319, propane / gasoline (25% load) | $0.60 | $0.61 | USD/hour |
| Generac Guardian 10 kW, propane (1/2 to full load) | $2.61 | $3.98 | USD/hour |
| Generac Guardian 24 kW, propane (1/2 to full load) | $6.80 | $10.49 | USD/hour |
| Generac Guardian 24 kW, natural gas (Feb price 1/2 load to Jul price full load) | $3.03 | $8.09 | USD/hour |
| Honda inverters, fuel cost of power | $0.53 | $0.99 | USD/kWh |
Fuel prices used in this guide
Every running cost below is a fuel-use figure from the maker multiplied by one of these national average prices. Put your local price in place of ours to get your own figure.
| Fuel | US average price | Date | Source |
|---|---|---|---|
| Regular gasoline | $3.805 a gallon | Week of 16 November 2026 ($3.995 on 9 November, $4.153 on 2 November) | EIA weekly retail survey |
| On-highway diesel | $5.937 a gallon | Week of 16 November 2026 | EIA weekly retail survey |
| Residential propane | $2.689 a gallon, before tax | Week of 19 October 2026, the latest week on EIA’s state table when we checked on 22 November; its national series showed $2.817 for the week of 16 November, 4.8% higher, so add about 5% to the propane costs here | EIA heating fuel survey |
| Residential natural gas | $26.45 per thousand cubic feet; $14.95 in February | July 2026, the latest month shown; February 2026 for comparison | EIA natural gas prices |
| Residential electricity | 18.16 cents per kWh | August 2026 | EIA Electric Power Monthly, Table 5.3 |
Two cautions about these prices. EIA’s monthly residential natural gas average rose from $14.95 per thousand cubic feet in February 2026 to $26.45 in July, so we show standby costs at both. And a small propane cylinder bought by exchange usually costs more per gallon than propane delivered to a home tank. We have no dated national price for cylinder exchanges, so treat the propane cost for the portable generator below as a floor.
Portable generator fuel cost per hour
Makers publish a tank size and a run time at a stated load. Dividing the tank by the run time gives gallons per hour, and multiplying by $3.805 gives the fuel cost per hour. Dividing again by the kilowatts being delivered gives the cost per kilowatt-hour.
| Generator (maker’s list price) | Load | Tank and published run time | Fuel per hour | Cost per hour | Cost per kWh |
|---|---|---|---|---|---|
| Honda EU2200i ($1,199) | Rated, 1,800 W | 0.95 gal, 3.2 hours | 0.30 gal | $1.13 | $0.63 |
| Honda EU2200i | Quarter load, 450 W | 0.95 gal, 8.1 hours | 0.12 gal | $0.45 | $0.99 |
| Honda EU3200i ($2,799) | Rated, 2,600 W | 1.2 gal, 3.3 hours | 0.36 gal | $1.38 | $0.53 |
| Honda EU3200i | Quarter load, 650 W | 1.2 gal, 8.6 hours | 0.14 gal | $0.53 | $0.82 |
| Honda EU7000iS ($4,899) | Rated, 5,500 W | 5.1 gal, 6.4 hours | 0.80 gal | $3.03 | $0.55 |
| Honda EU7000iS | Quarter load, 1,375 W | 5.1 gal, 16.0 hours | 0.32 gal | $1.21 | $0.88 |
| Westinghouse WGen7500 ($1,049) | 25% load, about 1,875 W | 6.6 gal, up to 11 hours | 0.60 gal | $2.28 | $1.22 |
| Champion 201319 dual fuel, on gasoline | 25% load, about 875 W | 2.25 gal, up to 14 hours | 0.16 gal | $0.61 | $0.70 |
| Champion 201319 dual fuel, on propane | 25% load, about 790 W | 20 lb cylinder (about 4.7 gal), up to 21 hours | 0.22 gal | $0.60 | $0.77 |
Specifications and list prices from the makers’ own product pages, read on 22 November 2026: Honda EU2200i, EU3200i, EU7000iS, Westinghouse WGen7500 and Champion 201319. Honda prices are the 49-state versions; the 50-state EU3200i and EU7000iS are listed at $2,899 and $4,999. Champion’s page showed no price. Fuel per hour, cost per hour and cost per kWh are our calculations. Quarter-load watts are a quarter of the rated or running watts. Propane is counted at about 4.2 lb a gallon.
Read the load column before comparing rows. Honda quotes run time at rated load and at a quarter of it, while Westinghouse and Champion quote a best case, “up to” a number of hours at 25% load, so their real fuel use may be higher than the table shows. Champion’s specification table gives the tank as 2.25 gallons and its description says 2.3; we used 2.25.
Home standby generator cost per hour
Generac publishes fuel use at half load and at full load for its air-cooled Guardian series, in cubic feet of natural gas and gallons of propane per hour. It calls them approximate values and points owners to the specification sheet or the fuel data decal on the unit for exact figures. At the EIA prices above they work out as follows.
| Guardian size | Natural gas, half to full load | Cost per hour at $14.95 (February) | Cost per hour at $26.45 (July) | Propane, half to full load | Cost per hour at $2.689 |
|---|---|---|---|---|---|
| 10 kW | 101 to 127 cu ft | $1.51 to $1.90 | $2.67 to $3.36 | 0.97 to 1.48 gal | $2.61 to $3.98 |
| 14 kW | 195 to 256 cu ft | $2.92 to $3.83 | $5.16 to $6.77 | 1.81 to 3.07 gal | $4.87 to $8.26 |
| 18 kW | 169 to 247 cu ft | $2.53 to $3.69 | $4.47 to $6.53 | 1.70 to 3.02 gal | $4.57 to $8.12 |
| 22 kW | 204 to 327 cu ft | $3.05 to $4.89 | $5.40 to $8.65 | 2.53 to 3.90 gal | $6.80 to $10.49 |
| 24 kW | 203 to 306 cu ft | $3.03 to $4.57 | $5.37 to $8.09 | 2.53 to 3.90 gal | $6.80 to $10.49 |
| 26 kW | 188 to 333 cu ft | $2.81 to $4.98 | $4.97 to $8.81 | 2.06 to 3.63 gal | $5.54 to $9.76 |
Fuel use from Generac’s support article on standby fuel use, read on 22 November 2026. Costs per hour are our calculations.
Generac’s diesel Protector units use 0.79 to 1.48 gallons an hour at 15 kW, 1.05 to 1.98 at 20 kW and 1.45 to 2.74 at 30 kW, again from half load to full load. At EIA’s on-highway diesel price of $5.937 that is $4.69 to $8.79, $6.23 to $11.76 and $8.61 to $16.27 an hour. The on-highway price includes road taxes, and standby generators normally burn dyed off-road diesel sold without them, so read these as upper figures. We have no dated national price for off-road diesel.
What a 24-hour outage costs in fuel
Multiplying the hourly figures by 24 shows how much fuel a full day without mains power needs, and how much has to be stored.
| Generator and load | Fuel in 24 hours | Fuel cost |
|---|---|---|
| Honda EU2200i at quarter load (450 W) | 2.81 gal of gasoline | $10.71 |
| Honda EU7000iS at quarter load (1,375 W) | 7.65 gal of gasoline | $29.11 |
| Westinghouse WGen7500 at 25% load (about 1,875 W) | 14.4 gal of gasoline | $54.79 |
| Honda EU7000iS at rated load (5,500 W) | 19.1 gal of gasoline | $72.77 |
| Generac Guardian 10 kW at half load, propane | 23.3 gal of propane | $62.60 |
| Generac Guardian 24 kW at half load, propane | 60.7 gal of propane | $163.28 |
| Generac Guardian 24 kW at half load, natural gas | 4,872 cu ft | $72.84 to $128.86 |
Storage is the practical limit. Propane tanks are normally filled to about 80%, so a 500-gallon tank holds about 400 gallons. At the Guardian 24 kW’s half-load rate of 2.53 gallons an hour that lasts about 158 hours, or 6.6 days, and at full load about 103 hours, or 4.3 days. The 10 kW unit at half load would run about 412 hours, a little over 17 days, on the same tank. A gasoline EU7000iS held at rated load needs 19 gallons a day, which is nearly four 5-gallon cans.
Our analysis: what the numbers show
- Generator power costs about three to five times grid power. The three Hondas deliver a kilowatt-hour for $0.53 to $0.99 of gasoline, against a US residential average of 18.16 cents in August 2026. That is 2.9 to 5.5 times the grid price before the cost of the machine. A generator earns its keep in outages and off-grid work, not by lowering a power bill.
- Light loads waste fuel per unit of power. At quarter load the hourly cost falls to 38% to 40% of the rated-load figure, but each kilowatt-hour costs 53% to 60% more: $0.99 against $0.63 on the EU2200i and $0.88 against $0.55 on the EU7000iS.
- An oversized generator costs more for the same job. The EU7000iS at quarter load supplies 1,375 W for $1.21 an hour. The EU2200i at its full rated 1,800 W supplies more power for $1.13.
- Fuel savings alone do not repay a premium inverter. At light load the open-frame WGen7500 burns 0.60 gallons an hour and the EU7000iS 0.32, a difference of about $1.07 an hour. The Honda’s list price is $3,850 higher, so it would take about 3,600 running hours, 150 days around the clock, to recover the gap from fuel. The comparison is rough, because the two loads differ (about 1,875 W against 1,375 W) and Westinghouse’s figure is a best case. Per kilowatt-hour the WGen7500 costs about 38% more. The stronger reasons to pay for the inverter are elsewhere: Honda lists 58 dB(A) at rated load and Westinghouse 72 dBA, though the two makers may not measure at the same distance.
- Natural gas is the cheapest standby fuel at these averages. A 24 kW Guardian at half load costs $3.03 to $5.37 an hour on natural gas and $6.80 on propane. Propane is 27% dearer than natural gas at the July price and more than twice the cost at the February price. At full load on February-priced gas the 24 kW unit produces a kilowatt-hour for about $0.19, close to the grid average; on propane it is about $0.44.
- A bigger standby unit is not always thirstier. At half load the 26 kW Guardian uses less fuel than the 22 kW (188 against 204 cubic feet of gas, 2.06 against 2.53 gallons of propane), and the 18 kW uses less than the 14 kW. Generac’s article says newer designs can be more efficient. On propane at half load the 26 kW costs about $30 a day less to run than the 22 or 24 kW, so compare fuel tables as well as kilowatts.
- The fuel price moves the bill quickly. US regular gasoline fell from $4.153 to $3.805 a gallon between 2 and 16 November 2026, a drop of 8.4%. A day at rated load on the EU7000iS went from $79.43 to $72.77.
How to work out your own generator’s running cost
- Find the fuel tank size and the run time in the specifications, and note the load the run time is quoted at.
- Divide the tank size in gallons by the run time in hours to get gallons per hour.
- Multiply by your local fuel price to get the cost per hour.
- Divide by the kilowatts supplied at that load to get the cost per kilowatt-hour.
For the EU2200i at rated load: 0.95 gallons divided by 3.2 hours is 0.30 gallons an hour, times $3.805 is $1.13 an hour, divided by 1.8 kW is $0.63 a kilowatt-hour. For a standby unit, take the maker’s cubic feet per hour and multiply by your gas price per cubic foot. Gas bills are usually priced per therm or per hundred cubic feet, and one hundred cubic feet is roughly one therm, so 203 cubic feet an hour is close to two therms an hour.
Treat any result as an estimate. Fuel use changes with the load, and a home’s draw during an outage rises and falls, with short peaks when a well pump, furnace blower or air conditioner starts.
What fuel cost leaves out
- The machine and its installation. See our guides to portable generator prices, Generac standby generator costs and commercial generator prices.
- Oil and servicing. Makers set oil-change and service intervals in running hours, so a long outage brings them round quickly. The schedule is in the owner’s manual.
- Self-test runs. Standby units run short exercise cycles between outages, which use a little fuel all year.
- Stored fuel. Gasoline does not keep indefinitely, so follow the maker’s guidance on storage and stabiliser, and rotate what you keep.
- Safety. The US Consumer Product Safety Commission says to run a portable generator outdoors only, at least 20 feet from the house, with the exhaust pointed away from doors and windows, because of carbon monoxide.
For a refrigerator, lights and phone charging over a short outage, a battery unit is the other option; our portable power station price guide covers what those cost.
FAQs
How much does it cost to run a generator per hour? About $0.45 to $3.03 an hour for the portable gasoline models we checked, at $3.805 a gallon, and about $1.51 to $10.49 an hour for a 10 to 26 kW home standby unit, depending on load and on whether it burns natural gas or propane.
How much gas does a generator use in 24 hours? From the makers’ run times, a Honda EU2200i at quarter load uses about 2.8 gallons in 24 hours and a Honda EU7000iS about 7.7 gallons at quarter load or 19 gallons at rated load.
Is it cheaper to run a generator on propane or natural gas? Natural gas, at EIA’s national averages. A 24 kW Generac Guardian at half load costs $3.03 to $5.37 an hour on natural gas, depending on the month’s price, and $6.80 an hour on propane at $2.689 a gallon.
Is running a generator cheaper than grid electricity? No. The gasoline models we checked cost $0.53 to $0.99 per kilowatt-hour in fuel alone, against a US residential average of 18.16 cents in August 2026.
How long will a 500-gallon propane tank run a whole-house generator? With about 400 usable gallons, roughly 6.6 days at half load or 4.3 days at full load on a 24 kW Generac Guardian, using Generac’s approximate fuel figures.
Does a bigger generator use more fuel? Usually, but not always. A large portable running a small load burns more than a small one working hard, and Generac’s 26 kW Guardian uses less fuel at half load than its 22 kW model.
Updated 22 November 2026. Sources: EIA weekly gasoline and diesel prices (16 November 2026), EIA residential propane (week of 19 October 2026), EIA residential natural gas (February and July 2026) and EIA Electric Power Monthly Table 5.3 (August 2026); Honda, Westinghouse and Champion product pages; Generac’s standby fuel-use article. All costs per hour, per day and per kilowatt-hour are our calculations from those figures. Fuel prices change weekly and vary by region, so recalculate with your local price.